Search results for "electric [mass]"
showing 10 items of 1101 documents
A comparison of lateral popliteal versus lateral midfemoral sciatic nerve blockade using ropivacaine 0.5%
2004
The midfemoral approach to the sciatic nerve (MF) is a new technique that has been used for postoperative analgesia after knee surgery. The aim of the present study was to compare efficacy, performance time, and patient acceptance of the midfemoral approach to that of the lateral approach at the level of the popliteal fossa (popliteal block [PB]).Sixty-three patients were enrolled in this prospective, randomized study. Thirty-two patients received a lateral sciatic nerve block (group PB) and 31 patients a midfemoral block (group MF). Ropivacaine 0.5% (30 mL) was used in both groups.The quality of nerve blockade was comparable in both groups. Onset of sensory block for peroneal and tibial ne…
Modulation of adrenergic responses of human vas deferens by K+ channel inhibitors.
2010
Objectives The present study was designed to evaluate the role of K + channels in the adrenergic responses of human vas deferens as well as the intervention of dihydropyridine-sensitive Ca 2+ channels on modulation of adrenergic responses by K + channel inhibitors. Methods Ring segments of the epididymal part of the vas deferens were taken from 32 elective vasectomies and mounted in organ baths for isometric recording of tension. We then studied the effects of K + channel blockers on neurogenic and norepinephrine-induced contractile responses. Results Addition of tetraethylammonium (TEA, 10 −3 M), a nonspecific K + channel blocker, or charybdotoxin (10 −7 M), a nonselective inhibitor of lar…
Electrical impedance spectroscopy as a potential adjunct diagnostic tool for cutaneous melanoma.
2012
Background Previous studies have shown statistically significant differences in electrical impedance between various cutaneous lesions. Electrical impedance spectroscopy (EIS) may therefore be able to aid clinicians in differentiating between benign and malignant skin lesions. Objectives The aim of the study was to develop a classification algorithm to distinguish between melanoma and benign lesions of the skin with a sensitivity of at least 98% and a specificity approximately 20 per cent higher than the diagnostic accuracy of dermatologists. Patients/Methods A total of 1300 lesions were collected in a multicentre, prospective, non-randomized clinical trial from 19 centres around Europe. Al…
Clinical performance of the Nevisense system in cutaneous melanoma detection: an international, multicentre, prospective and blinded clinical trial o…
2014
Summary Background Even though progress has been made, the detection of melanoma still poses a challenge. In light of this situation, the Nevisense electrical impedance spectroscopy (EIS) system (SciBase AB, Stockholm, Sweden) was designed and shown to have the potential to be used as an adjunct diagnostic tool for melanoma detection. Objectives To assess the effectiveness and safety of the Nevisense system in the distinction of benign lesions of the skin from melanoma with electrical impedance spectroscopy. Methods This multicentre, prospective, and blinded clinical study was conducted at five American and 17 European investigational sites. All eligible skin lesions in the study were exami…
Precursors of the evoked K-complex in event-related brain potentials in stage 2 sleep.
1997
The aim of the study was to examine precursors of the evoked K-complex as manifested in event-related brain potentials (ERPs) during stage 2 sleep. ERPs to infrequent deviant tones of 1100 and 2000 Hz and immediately preceding frequent standard tones of 1000 Hz were compared between trials containing and trials not containing a K-complex (KC trials, NO KC trials, respectively) to the deviant tones. The N350 wave to the deviant tones was markedly larger during the KC than during the NO KC trials. Also the P210 wave to the 2000 Hz deviant tone showed the same phenomenon. No definite evidence was found for the mismatch negativity-like deflection during the KC trials. ERPs to the standard tones…
Quadriceps Femoris Torque and EMG Activity in Seated versus Supine Position
2003
To compare voluntary and electrically evoked knee extensor torque, surface electromyography (EMG), and activation level obtained under seated versus supine position, i.e., with shortened versus lengthened rectus femoris (RF) muscle.The knee extensor torque obtained during maximal voluntary contractions (MVC) and after single and paired stimuli applied at rest was measured under seated (i.e., 90 degrees hip angle) and supine (i.e., 180 degrees hip angle) conditions. The associated EMG activity from biarticular RF and monoarticular vasti was also recorded, and activation level was estimated by means of the twitch interpolation technique.Knee extensor MVC was 10.6% higher in the seated compare…
Comparative effects of dilator drugs on human penile dorsal artery and deep dorsal vein
1998
The present study was designed to characterize the response of human penile dorsal artery and deep dorsal vein to dilator drugs used in the diagnosis and treatment of erectile dysfunction with special emphasis on the effects on sympathetic neurotransmission. Ring segments of penile dorsal artery and deep dorsal vein were obtained from 20 multi-organ donors during procurement of organs for transplantation. The rings (3 ;mm long) were suspended in organ bath chambers for isometric recording of tension. We then studied the relaxant responses to prostaglandin E1 (PGE1), vasoactive intestinal peptide (VIP), papaverine (PV), sodium nitroprusside (SNP) and linsidomine chlorhydrate (SIN-1), and ana…
Influence of Endothelial Nitric Oxide on Adrenergic Contractile Responses of Human Cerebral Arteries
1996
The present study was designed to investigate the influence of the endothelium and that of the L-arginine pathway on the contractile responses of isolated human cerebral arteries to electrical field stimulation (EFS) and norepinephrine. Rings of human middle cerebral artery were obtained during autopsy of 19 patients who had died 3–8 h before. EFS (1–8 Hz) induced frequency-dependent contractions that were abolished by tetrodotoxin, prazosin, and guanethidine (all at 10-6 M). The increases in tension were of greater magnitude in arteries denuded of endothelium. NG-monomethyl L-arginine (L-NMMA 10-4 M) potentiated the contractile response to EFS in artery rings with endothelium but did not …
Stress and thermoregulation: different sympathetic responses and different effects on experimental pain.
2009
Stress and thermoregulation both activate the sympathetic nervous system (SNS) but might differently affect pain. Studies investigating possible interactions in patients are problematic because of the high prevalence of SNS disturbances in patients. We therefore analyzed the influence of these different sympathetic challenges on experimentally-induced pain in healthy subjects. SNS was activated in two different ways: by mental stress (Stroop task, mental arithmetic task), and by thermoregulatory stimulation using a water-perfused thermal suit (7 degrees C, 32 degrees C, or 50 degrees C). Attentional effects of the mental stress tasks were controlled by using easy control tasks. Both, stress…
Influence of Delay Period Duration on Inhibitory Processes for Response Preparation.
2015
In this study, we examined the dynamics of inhibitory preparatory processes, using a delayed response task in which a cue signaled a left or right index finger (Experiment 1) or hand (Experiment 2) movement in advance of an imperative signal. In Experiment 1, we varied the duration of the delay period (200, 500, and 900 ms). When transcranial magnetic stimulation (TMS) was applied 100 ms before the imperative, motor evoked potentials (MEPs) elicited in the first dorsal interosseous were strongly inhibited. For delays of 500 ms or longer, this inhibition was greater when the targeted muscle was selected compared with when it was not selected. In contrast, the magnitude of inhibition just aft…